PhotoniQ Multi-Channel PMT, APD, and SPM Data Acquisition Systems

To meet the needs of most applications, Vertilon offers the PhotoniQ data acquisition (DAQ) system in four standard configurations. All configurations include PC compatible GUI software, Windows based USB drivers, USB cable, and external system power supply. As an option, a negative high voltage module to bias user-supplied PMTs or APDs can be added to any PhotoniQ model. A second high voltage module can be optionally added to the 64 channel PhotoniQ models. All models of PhotoniQ photomultiplier tube DAQ systems can be optionally upgraded with a large event buffer memory that can be used in applications requiring high speed continuous data acquisition. For a comprehensive description of the features, specifications, and options for all PhotoniQ models, download the PhotoniQ User Manual and Selection Guide here.
User Manual:
PhotoniQ Data Acquisition (DAQ) Systems
Selection Guide:
PhotoniQ Data Acquisition (DAQ) Systems

PhotoniQ IQSP480 32 Channel Data Acquisition System IQSP480 — 32 Channel Data Acquisition (DAQ) System
96 dB dynamic range (16 bits)
6.0 usec event pair resolution
150 KHz maximum trigger rate
2000 pC maximum input charge
30 fC RMS equivalent input noise charge
Product Sheet: IQSP480 32 Channel Data Acquisition (DAQ) System
PhotoniQ IQSP482 64 Channel Data Acquisition System IQSP482 — 64 Channel Data Acquisition (DAQ) System
96 dB dynamic range (16 bits)
7.0 usec event pair resolution
120 KHz maximum trigger rate
2000 pC maximum input charge
30 fC RMS equivalent input noise charge
Product Sheet: IQSP482 64 Channel Data Acquisition (DAQ) System
PhotoniQ IQSP580 32 Channel Data Acquisition System IQSP580 — 32 Channel High Speed Data Acquisition (DAQ) System
84 dB dynamic range (14 bits)
2.5 usec event pair resolution
390 KHz maximum trigger rate
500 pC maximum input charge
55 fC RMS equivalent input noise charge
Product Sheet: IQSP580 32 Channel Data Acquisition (DAQ) System
PhotoniQ IQSP582 64 Channel Data Acquisition System IQSP582 — 64 Channel High Speed Data Acquisition (DAQ) System
84 dB dynamic range (14 bits)
3.2 usec event pair resolution
250 KHz maximum trigger rate
500 pC maximum input charge
55 fC RMS equivalent input noise charge
Product Sheet: IQSP582 64 Channel Data Acquisition (DAQ) System